Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
Response time
t90 starting at < 1,5 s iTHERM QuickSens depending on configuration
Max. process pressure (static)
depending on the configuration
Operating temperature range
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 basic TF: -50 °C ...200 °C (-58 °F ...392 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
iTHERM ModuLine TM112 is an easy-to-use imperial direct contact modular thermometer, featuring outstanding RTD or TC sensor technology. It is suitable for every application, from basic functionality to high-end performance in the chemical, oil & gas and power & energy industries.
For universal use
Measuring range: –200 to +1 100 °C (–328 to +2 012 °F)
Pressure range: up to 75 bar (1 088 psi)
Benefícios
User-friendly and reliable from product selection to maintenance
iTHERM inserts: full traceability and consistently high product quality for reliable measured values
iTHERM QuickSens: fastest response times of 1.5 s for optimum process control
Como a temperatura do hidrogênio comprimido aumenta com a expansão durante o abastecimento, a medição da temperatura é essencial nas estações de abastecimento de hidrogênio por motivos de segurança.
Nosso sensor de temperatura não invasivo pode ser facilmente adaptado ao tubo existente e integrado ao sistema de controle para permitir a operação eficiente em standby de turbogeradores.
O sensor de temperatura não invasivo iTHERM SurfaceLine TM611 mede a temperatura com precisão e rapidez, otimizando o desempenho e a eficiência do trocador de calor.
O processo Ziegler-Natta utiliza produtos químicos perigosos, como o tetracloreto de titânio. A medição precisa da temperatura é crucial para evitar reações descontroladas e garantir a segurança e a eficiência.
imperial style universal range of application suitable for hazardous areas can be used with iTHERM StrongSens, iTHERM QuickSens direct process contact
Thermowell / protection tube
without, direct process contact
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
Insert: 1/8" 1/4" 3/8" 3/8" reduziert auf 3/16" 3,0 mm 6,0 mm
Max. immersion length on request
up to 180"
Material protection tube/ thermowell
Insert Material: 316L (1.4404) Alloy 600 (2.4816)
Process connection
Thread: NPT1/2", NPT3/4" Compression fitting, also spring load: NPT1/4", NPT1/2"
Tip shape
straight stepped
Surface roughness Ra
0,76 μm (30 μin.) 1,6 μm (63,0 μin.)
Operating temperature range
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 basic TF: -50 °C ...200 °C (-58 °F ...392 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
Max. process pressure (static)
depending on the configuration
Accuracy
Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
Response time
t90 starting at < 1,5 s iTHERM QuickSens depending on configuration
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
WirelessHART communication interface Transmission rate: Nominal 250 kBits/s Operating frequency: 2.4 GHz (ISM band) Transmission range under reference conditions: Outdoor 250 m, indoor 50 m
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
WirelessHART communication interface Transmission rate: Nominal 250 kBits/s Operating frequency: 2.4 GHz (ISM band) Transmission range under reference conditions: Outdoor 250 m, indoor 50 m