Especificações resumidas
-
Max. measurement error
Mass flow: ±0.5 % of batch
-
Measuring range
0 to 150 kg/min (0 to 330 lb/min)
-
Medium temperature range
–50 to +125 °C (–58 to +257 °F)
-
Max. process pressure
350 bar (5080 psi)
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316)
Campo de aplicação
When it comes to billing and paying for the amount of CNG actually pumped, the measuring accuracy at the dispenser is just as important as with any other fuel. Therefore, the “brain” in every CNG dispenser is a flowmeter that measures the quantity of fuel transferred from dispenser to vehicle with the absolute highest accuracy – reliability day in, day out, round the clock. These are some of the benefits of CNGmass, which has been specifically designed for such applications.
Measuring principle operates independently of physical fluid properties such as viscosity or density
Accurate measurement of compressed natural gas (CNG) in high-pressure refueling applications.
Device properties
Flow rates up to 150 kg/min (330 lb/min)
Process pressure up to 350 bar (5080 psi)
Rupture disc available
Robust, ultra-compact transmitter housing
Pulse output and Modbus RS485
Transmitter for custody transfer
Benefícios
Excellent operational safety – reliable under extreme process conditions
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in/outlet run needs
Easy operation – reduced to application needs
Fast commissioning – pre-configured devices
-
Automatic recovery of data for servicing
Vídeos
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
Versões FLEX | Excelência técnica | Simplicidade |
---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
-
-
Informações Técnicas (TI)
CNGmass Technical Information
Versão em inglês - 02/2023
Coriolis flowmeter The refueling application flowmeter with easy system integration
EN PT 03/02/202324/05/201701/03/201601/08/201501/04/2010Idioma:
Inglês
Versão:
03/02/2023
Tamanho do arquivo:
1.3 MB
Nome do arquivo:
TI00077DEN_1623.pdf
-
-
-
Informações Técnicas (TI)
CNGmass Technical Information
Coriolis flowmeter
The refueling application flowmeter with easy system integrationEN PT 03/02/202324/05/201701/03/201601/08/201501/04/2010Idioma:
Inglês
Versão:
03/02/2023
Tamanho do arquivo:
1.3 MB
Nome do arquivo:
TI00077DEN_1623.pdf
-
-
-
Instruções de Operação (BA)
CNGmass MODBUS RS485 Operating Instructions and Description of Device Functions
Coriolis flowmeter
For fueling with Compressed Natural Gas (CNG)EN PT 20/06/202224/05/201701/03/201618/09/201501/04/2010Idioma:
Inglês
Versão:
20/06/2022
Tamanho do arquivo:
1.4 MB
Nome do arquivo:
BA00123DEN_1622.pdf
-
-
-
Instruções curtas (KA)
CNGmass Resumo das instruções de operação
Medidor de vazão Coriolis
EN PT 28/09/201501/04/2010Idioma:
Português
Versão:
28/09/2015
Tamanho do arquivo:
1 MB
Nome do arquivo:
KA00047DPT_1315.pdf
-
-
-
Instruções de Instalação (EA)
Replacing electronics module Installation Instructions
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM
EN PT 17/12/201808/11/2010Idioma:
Inglês
Versão:
17/12/2018
Tamanho do arquivo:
295.2 KB
Nome do arquivo:
EA00057DA2_1418.pdf
-
-
-
Instruções de Instalação (EA)
Electrical trace heating systems
Promass 100, 200, 300, 500, 500-digital, LNGmass, CNGmass, LPGmass
EN PT 01/03/2021Idioma:
Inglês
Versão:
01/03/2021
Tamanho do arquivo:
883.1 KB
Nome do arquivo:
EA01339DA2_0121.pdf
-
-
-
Instruções de Instalação (EA)
EA Replacing cover and O-ring
Proline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN PT 15/10/202401/10/201828/06/2012Idioma:
Inglês
Versão:
15/10/2024
Tamanho do arquivo:
797.3 KB
Nome do arquivo:
EA00098DA2_1624-00.pdf
-
-
-
Instruções de Instalação (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN PT 01/03/201828/11/201325/04/2013Idioma:
Inglês
Versão:
01/03/2018
Tamanho do arquivo:
139.5 KB
Nome do arquivo:
EA01051DA2_0318.pdf
-
-
-
Instruções de Instalação (EA)
Exchanging lead seal Installation Instructions
Promag 51, Promass 84, CNGmass DCI 8DF, LPGmass 8FE, CNGmass 8FF
EN PT 01/04/201904/12/201430/03/2010Idioma:
Inglês
Versão:
01/04/2019
Tamanho do arquivo:
213.1 KB
Nome do arquivo:
EA00044DA2_1419.pdf
-
-
-
Instruções de Segurança Ex (XA)
CNGmass Division 1 Ex documentation
Safety instructions for electrical apparatus for explosion-hazardous
areas classified
according to the National Electrical Code (NEC) and Canadian Electrical
Code (CEC)Idioma:
Inglês
Versão:
01/11/2015
Tamanho do arquivo:
417.6 KB
Nome do arquivo:
XA01374DEN_0116.pdf
-
-
-
Instruções de Segurança Ex (XA)
CNGmass NEC/CEC Division 1 Ex-documentation
Ex documentation for the operating instruction:
BA00123DEN PT 06/08/201201/07/2010Idioma:
Inglês
Versão:
06/08/2012
Tamanho do arquivo:
272.5 KB
Nome do arquivo:
XA00149DEN_1312.pdf
-