Especificações resumidas
-
Max. process pressure (static)
500 bar (7252 psi)
-
Maximum standard immersion length
900 mm (35,43")
-
Max. immersion length on request
5.000 mm (196,85")
Campo de aplicação
Due to the challenging process conditions by heavy duty applications the load capacity of a thermowell must be calculated exactly. Dye penetration tests, ultrasound test, helium leakage test, pressure endurance test as well as various, non-destructive material tests prove the quality of materials and processing.
TA550 is designed for use with resistance and thermocouple thermometers mainly in heavy duty applications.
Benefícios
The extension and the immersion lengths as well as the bar dimensions can be chosen according to process requirements
A wide choice of standard materials and process connections is available; other versions can be ordered according to specification
Different grades of surface finishing are also available
The process connection can be threaded or flanged weld
Seleção Extended
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
Versões FLEX | Excelência técnica | Simplicidade |
---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
-
-
Informações Técnicas (TI)
Technical Information
Omnigrad TA series
Industrial protecting tubesEN PT 26/09/2005Idioma:
Inglês
Versão:
26/09/2005
Tamanho do arquivo:
127.9 KB
Nome do arquivo:
TI138ten.pdf
-
-
-
Informações Técnicas (TI)
Technical information TA550
Industrial protecting tube
omnigrad TA550
Heavy duty - General purpose
From round bar stock - Ø 30 mm
3/4" NPT threaded or flanged weld type
Also ME U 819.02 - type 2EN PT 01/05/2001Idioma:
Inglês
Versão:
01/05/2001
Tamanho do arquivo:
98 KB
Nome do arquivo:
TI153ten_0501.pdf
-
-
-
Instruções de Operação (BA)
Thermowells
Operating instructions for thermowells for EAC approval
EN PT 01/12/2016Idioma:
Inglês
Versão:
01/12/2016
Tamanho do arquivo:
1.3 MB
Nome do arquivo:
BA01469TEN_0116.pdf
-
-
-
Documentação especial (SD)
Device viewer
Technical documentation in other languages
Idioma:
Inglês
Versão:
14/07/2021
Tamanho do arquivo:
478.5 KB
Nome do arquivo:
SD02429R09EN_0121.pdf
-
-
-
Campos de atividades (FA)
Misura della temperatura
Misura della temperatura
Termometri e trasmettitori per l'industria di processoIdioma:
Italiano
Versão:
09/07/2024
Tamanho do arquivo:
20.3 MB
Nome do arquivo:
FA00006Tit_2223.pdf
-
-
-
Campos de atividades (FA)
Temperaturmesstechnik
Thermometer und Transmitter für die Prozessindustrie
Idioma:
Alemão
Versão:
17/05/2023
Tamanho do arquivo:
17.9 MB
Nome do arquivo:
FA00006Tde_2223_online.pdf
-
-
-
Campos de atividades (FA)
Misura della temperatura
Termometri e trasmettitori per l'industria di processo
Idioma:
Italiano
Versão:
17/02/2020
Tamanho do arquivo:
30.6 MB
Nome do arquivo:
FA00006TIT_2020.pdf
-
-
-
Campos de atividades (FA)
温度計
プロセス産業向けの温度計
および伝送器Idioma:
Japonês
Versão:
17/02/2020
Tamanho do arquivo:
38.9 MB
Nome do arquivo:
FA00006TJA_2020.pdf
-
-
-
Campos de atividades (FA)
Mesure de température
Capteurs et transmetteurs de température pour les industries de process
Idioma:
French
Versão:
20/12/2019
Tamanho do arquivo:
60.9 MB
Nome do arquivo:
FA00006TFR-Mesure de temperature.pdf
-
-
-
Campos de atividades (FA)
Temperature measurement
Thermometers and transmitters for the process industry
Idioma:
Inglês
Versão:
17/05/2023
Tamanho do arquivo:
18 MB
Nome do arquivo:
FA00006Ten_2223_online.pdf
-